Pipe Heating Cable of UL
Feature
1. voltage 110v to 120v
2.Length 0.91m to 24.38m etc
3.offer manual.
4.2 feet power line.
ModelPower
WattOhmLength
MLength
FTAmpsThermostat
±3ºCPowerlineColorDiameter
±0.3mmJointprocessingSHPT-7W-3FT(120V)21685.70.9130.26ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-6FT(120V)42342.91.8360.46ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-12FT(120V)84171.43.66120.76ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-18FT(120V)126114.35.49181.16ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-20FT(120V)140102.96.10201.26ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-24FT(120V)16885.77.32241.46ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-30FT(120V)21068.69.14301.86ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-40FT(120V)28051.412.19402.36ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-60FT(120V)42034.318.29603.56ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionSHPT-7W-80FT(120V)56025.724.38804.76ºC-13ºCAmericanindiatorplugL=2ftBlack5.0*13.2InjectionFrost-proof water pipes with this heating cable
calibre
15mm
22mm
28mm
35mm
42mm
48mm
60mm
76mm
Withoutpipeinsulation
-20°C.
-13°C.
-10°C.
-7°C.
-5°C.
-4°C.
-3°C.
-2°C.
With13mmpipeinsulation
-45°C.
-45°C.
-40°C.
-40°C.
-35°C.
-30°C.
-25°C.
-20°C.
Antifreeze Water Pipe Heating CableSpecification
Installation:
1firstunwindtheheatingcable.Thecablemustneverbeconnectedtothepowerlinewhenitiswoundup.
2ifthecableistooinflexiblebecauseoflowtemperatures,unwinditandputitforsomeminutesintotheplug.
3afterwardsyoucanpassthecable.
4theareaaroundthepipewhereyouwanttoconnectitwiththecablemustbeaccessiblyandnon-attached.
5theheatingcablecannotbepassedbehindwalls
6putthethermostatwiththeroundblackcontactareatightlyonthecoolestpointofthepipeandfixitwithinsulatingtape.
7finallyputthewholecableonthepipeandfastenitevery30~60cmwithinsulatingtape.
8attention:thecablemustbefasteningstraightonthepipe
9nowyoucancheckifyourcableworks.
10afterwardsinsulatethewaterpipeandtheheatingcablewithmineralrockwoolorfoam.Attention:neverusemorethan13mmofthismaterialtoinsulate.
11ingeneraltheheatingcablemustbeprotectedagainstmechanicaldamageorbiting.
12theheatingcablecannotbeputintoliquids.
13finallyplugthecableintoa230Vmainplug.We can do this product without thermostats(6 to 13 degree), because there are very heavy snow in winter in some Europe place, then the customers need more heat pipe heating cable, and we suggest the pipe heating cable without thermostats one.